ACR SmartReader Data Logger

Models
SmartReader 1 Temperature
SmartReader 2 Relative Humidity
SmartReader 3 3 Phase Current
SmartReader 4 Pressure
SmartReader 5 3 Channel Thermocouple
SmartReader 6 7 Channel Thermocouple
SmartReader 7 Process Signal
SmartReader 8 8 Channel Temperature
SmartReader 9 Pulse

Chinese version

ACR products
ACR JR
ACR OWL
Smart Reader
Smart Reader Plus
Nautilus
Power Watch

Home
Product Overview
Product Specifications
Software
Accessories
About AXIOM & ACR
Contact us
Site map

ACR SmartReader Common Specifications

Multi-channel, Configurable, 8 Bit Data Loggers
Front view Back view

Features

  • Multiple channels
  • Accessible remotely by modem
  • Multiple loggers can be linked to form a network
  • 32 K memory
  • 10-year battery life

Product Specifications (General)
SmartReader Data Loggers share many common features. Please refer to individual model specifications for further specifications.

Size 107 x 74 x 22 mm (4.2 x 2.9 x 0.9").
Weight 110 grams (3.75 ounces).
Case Materials NorylŪ Plastic.
Operating Limits -40oC to 70oC (-40oF to 158oF) and 0 to 95% Relative Humidity (non-condensing).
Clock Accuracy +/-2 seconds per day.
Battery 3.6 volt Lithium, 1 Amp-Hour.
Power Consumption 5 to 10 microamps (continuous).
Battery Life 10-years warrantied (under normal use). Factory replaceable.
External Connector Removable screw-type terminal strip with Common (-) connection.
Mounting Magnetic backing or locking eyelet.
Memory Size 32 K (32,767 readings).
Sampling Methods 1. Continuous (First-in, First-out).
2. Stop when full (Fill-then-stop).
Sampling Rates User selectable rates between 8 seconds to once every 5 days.
Resolution 8 bits (1 part in 256).
PC Requirements IBM PC or 100% compatible running MS Windows 3.1, '95, '98, or NT, with at least 2 MB RAM, 2 MB of hard drive disk space and one free serial port.
Product Approvals Meets Part 15 for Digital Devices of the Code of Federal Regulations of the Federal Communications Commission (FCC). Meets Class A radiated and conducted emission requirements of Section 2 of the Radio Interference Regulations of Communications Canada. IEC801-2, 3, 4 and EN55011 covering ESD, RFI Immunity, EFT/Burst and Radiated Emissions respectively for the Commission of the European Communities (CE).
Resistance to X-Rays Tested for protection against a 160kV dose @ 5mA for 30 seconds (150mA-sec) @ 38 inches F.F.D. (about 100 times that of an airport X-Ray machine). Tested for protection against Gamma Ray (equivalent to 0.137 - 1.38 mega volts) IR 192 - 28 curies @ 30 second exposure source to object distance 5".
Accuracy Curve Temperature Sensor Accuracy with ACR SmartReader
Software Specifications TrendReader - SmartReader Data Logger Software
RealTime Graphing Software
Remote & Network communications ACR SmartReader Networking and Remote Communications

Internal Temperature Sensor Specifications (Common on all models)
Type Negative Temperature Coefficient Thermistor. 10,000 ohms @ 25oC (77oF).
Tolerance (sensor only) +/-0.2oC, over the range of 0 to 70oC
(+/-0.3oF, over the range of 32 to 158oF).
Range -40 to 70oC (-40 to 158oF).
Resolution 0.4oC (0.7oF) @ 25oC. Better than 1oC (1.8oF) between -25oC ( -13oF) and 70oC (158oF). Better than 2.0oC (3.6oF) between -40oC ( -40oF) and -25oC ( -13oF).

Home | Product Overview | Product Specifications | Software | Accessories | About AXIOM & ACR | Contact us Site map

You are visitor number since 10th May 2000