ACR SmartReader Plus Common Specifications

Multi-channel, Configurable, 12 Bit Data Loggers
Front view Back view

Features

  • Multiple channels
  • Accessible remotely by modem
  • Multiple loggers can be linked to form a network
  • 32 K, 128 K or 1.5 MB memory
  • 10-year battery life

Product Specifications (General)
SmartReader Plus Data Loggers share many common features. Please refer to individual model specifications for further specifications.

Size 107 x 74 x 22 mm (4.2 x 2.9 x 0.9").
Weight 110 grams (3.75 ounces).
Case Materials NorylŪ Plastic.
Operating Limits -40oC to 70oC (-40oF to 158oF) and 0 to 95% Relative Humidity (non-condensing).
Clock Accuracy +/-2 seconds per day.
Battery 3.6 volt Lithium, 1 Amp-Hour.
Memory Sizes 32 K (21,500 readings).
128 K (87,000 readings).
1.5 MB (1,000,000 readings). See specific models for availability.
Sampling Methods 1. Continuous (First-in, First-out - not available with sample rates faster than 8 seconds).
2. Stop when full (Fill-then-stop).
Sampling Rates User selectable rates from 25 per second to one reading every 8 hours. (BP-101 battery pack or PS-201 Power Supply required for sample rates faster than 8 seconds. See Accessories section for details).
Resolution 12 bit (1 part in 4096).
Power Consumption 5 to 10 microamps (continuous).
Battery Life 10-years warrantied (under normal use). Factory replaceable.
PC Requirements IBM PC or 100% compatible running MS Windows 3.1, '95, '98, or NT, with at least 2 MB RAM, 2 MB of hard drive disk space and one free serial port.
Product Approvals Meets Part 15 for Digital Devices of the Code of Federal Regulations of the Federal Communications Commission (FCC). Meets Class A radiated and conducted emission requirements of Section 2 of the Radio Interference Regulations of Communications Canada. IEC801-2, 3, 4 and EN55011 covering ESD, RFI Immunity, EFT/Burst and Radiated Emissions respectively for the Commission of the European Communities (CE).
Resistance to X-Rays Tested for protection against a 160kV dose @ 5mA for 30 seconds (150mA-sec) @ 38 inches F.F.D. (about 100 times that of an airport X-Ray machine). Tested for protection against Gamma Ray (equivalent to 0.137 - 1.38 mega volts) IR 192 - 28 curies @ 30 second exposure source to object distance 5".
Accuracy Curve Temperature Sensor Accuracy with ACR SmartReader Plus
Software Specifications TrendReader - SmartReader Plus Data Logger Software
RealTime Graphing Software
Talk-Back Software
Remote & Network communications ACR SmartReader Plus Networking and Remote Communications

Internal Temperature Sensor Specifications (Common on all models, except model 9)
Type Negative Temperature Coefficient Thermistor. 10,000 ohms @ 25oC (77oF).
Tolerance (sensor only) +/-0.2oC, over the range of 0 to 70oC
(+/-0.3oF, over the range of 32 to 158oF).
Range -40 to 70oC (-40 to 158oF).
Resolution 0.03oC (0.05oF) at 25oC (77oF). Better than 0.07oC (0.12oF) between -25oC (-13oF) and 70oC (158oF). Better than 0.13oC (0.23oF) between -40oC (-40oF) and -25oC (-13oF).