ACR OWL model 400

Models
OWL100 Internal Temperature
OWL200 External Temperature
OWL300 Electric Current
OWL400 DC Voltage
OWL500 DC Current

Chinese version

ACR products
ACR JR
ACR OWL
Smart Reader
Smart Reader Plus
Nautilus
Power Watch

Home
Product Overview
Product Specifications
Software
Accessories
About AXIOM & ACR
Contact us
Site map

ACR OWL model 400 Specifications

Single Channel DC Voltage Data Logger

The OWL model 400 is a rugged and versatile data logger that records DC voltage with ease and convenience. Ideal for monitoring (through commercially available transducers) a wide variety of measurement parameters. All voltage signals can be converted into custom engineering units using TrendReader 'sŪ simple equation editor.

Features:

  • Optical alarm
  • 10-year battery life
  • 32 KB memory
  • User-configurable
  • Install inside equipment
OWL model 400 drawing    

Product Specifications
No. of Channels One. (External DC voltage).
Input Range 0 to 38.4 volts max. DC (software selectable ranges available).
Input Impedance Greater than 100 K ohms.
Accuracy +/-1% of full scale.
Memory Size 32 KB.
Accuracy Curve Temperature Sensor Accuracy with ACR OWL
Common Specifications ACR OWL Common Specifications
Software Specifications TrendReader - ACR OWL Data Logger Software

Order Information
MODEL MEMORY CATALOG#
OWL-400 PLASTIC 32 KB 01-0253

Home | Product Overview | Product Specifications | Software | Accessories | About AXIOM & ACR | Contact us Site map

You are visitor number since 10th May 2000